The high pass rate coming from our customers who have passed the exam after using our D-PST-MN-A-24 exam software, and our powerful technical team make us proudly say that our CramPDF is very professional. The after-sale customer service is an important standard to balance whether a company is better or not, so in order to make it, we provide available 24/7 online service, one-year free update service after payment, and the promise of "No help, full refund", so please be rest assured to choose our product if you want to pass the D-PST-MN-A-24 Exam.
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
Topic 4 |
|
Maybe on other web sites or books, you can also see the related training materials. But as long as you compare CramPDF's product with theirs, you will find that our product has a broader coverage of the certification exam's outline. You can free download part of exam practice questions and answers about EMC certification D-PST-MN-A-24 exam from CramPDF website as a try to detect the quality of our products. Why CramPDF can provide the comprehensive and high-quality information uniquely? Because we have a professional team of IT experts. They continue to use their IT knowledge and rich experience to study the previous years exams of EMC D-PST-MN-A-24 and have developed practice questions and answers about EMC D-PST-MN-A-24 exam certification exam. So CramPDF's newest exam practice questions and answers about EMC certification D-PST-MN-A-24 exam are so popular among the candidates participating in the EMC certification D-PST-MN-A-24 exam.
NEW QUESTION # 45
What safety equipment is critical to have on hand to avoid equipment failure before replacing any components in a Dell EMC PowerStore array?
Answer: D
Explanation:
When replacing any components in a Dell EMC PowerStore array, it is critical to have an Electrostatic Discharge (ESD) Kit on hand to avoid equipment failure. The ESD Kit typically includes tools like wristbands and gloves that help prevent static electricity from damaging the electronic components during the replacement process.
Before beginning any maintenance work on the PowerStore array, it is essential to:
Use the ESD wristband by attaching one end to your wrist and connecting the other end to a grounded object.
Wear ESD gloves to handle sensitive components.
Ensure that the work area is free from static-prone materials and conditions.
Follow the detailed safety precautions and procedures outlined in the PowerStore Installation and Service Guide1.
Using an ESD Kit is a standard safety practice in the maintenance of electronic equipment, as static electricity can cause irreparable damage to sensitive components. The Dell PowerStore Installation and Service Guide provides comprehensive safety instructions, including the use of ESD protection, to ensure the safe handling of replaceable units2.
NEW QUESTION # 46
When a Dell EMC PowerStore node powers up in service mode, what are the commands and sequence used from the appliance SSH client to restore the node back to normal?
Answer: B
Explanation:
When a Dell EMC PowerStore node powers up in service mode, the commands and sequence used from the appliance SSH client to restore the node back to normal are as follows:
Run the svc_rescue_state clear command to clear the boot mode and take the node out of service mode1.
Then, run the svc_node reboot command to reboot the node and return it to normal operational mode1.
It is important to follow this sequence to ensure that the node exits service mode correctly and reboots into normal mode without any issues. For more detailed instructions or if you encounter any problems during this process, refer to the Dell EMC PowerStore Service Scripts Guide or contact Dell EMC Support for assistance1.
NEW QUESTION # 47
Which reference source provides service information and FRU procedures for Dell EMC PowerStore?
Answer: B
Explanation:
The SolVe Tool is the reference source that provides service information and Field Replaceable Unit (FRU) procedures for Dell EMC PowerStore. The SolVe Tool is an online resource that offers step-by-step guidance for various procedures, including servicing and replacing hardware components, also known as FRUs1.
The tool is designed to help users and service technicians perform maintenance tasks accurately and efficiently. It includes detailed instructions, diagrams, and other helpful information that can assist in troubleshooting and resolving issues with Dell EMC PowerStore systems.
For accessing the SolVe Tool and finding the service information and FRU procedures for PowerStore, users can visit the Dell Support website and navigate to the SolVe Online section. Additionally, the PowerStore Info Hub provides a collection of product documentation and videos that can be useful for understanding the system's operation and maintenance2.
It is important to use the SolVe Tool and follow the provided instructions carefully to ensure that any service actions are performed correctly and safely, maintaining the integrity and performance of the PowerStore system.
NEW QUESTION # 48
Which component can be replaced while the Dell EMC PowerStore is up and running?
Answer: A
Explanation:
The component that can be replaced while the Dell EMC PowerStore is up and running is SFP (Small Form-factor Pluggable).
SFP modules are hot-swappable, meaning they can be replaced without powering down the system.
These modules are used for network connections and can be found in the network ports of the PowerStore appliance.
When replacing an SFP, it is important to ensure that the replacement is of the same type and speed as the one being replaced.
The process typically involves:
Removing the network cable from the SFP.
Unlocking the SFP from its socket.
Pulling the SFP out of the socket.
Inserting the new SFP into the socket until it clicks into place.
Reconnecting the network cable1.
For more detailed procedures on replacing SFP modules or other components, refer to the Dell PowerStore Installation and Service Guide or contact Dell Support for assistance.
NEW QUESTION # 49
What is a step in configuring the ToR data switches for a Dell EMC PowerStore T?
Answer: A
Explanation:
Configuring the Top of Rack (ToR) data switches for a Dell EMC PowerStore T involves several steps to ensure proper network setup and connectivity. One of the essential steps is to configure a port for the discovery laptop. This step is necessary for the initial discovery and configuration of the PowerStore appliances.
The process typically includes:
Identifying an unused port on the ToR switch that will be dedicated to the discovery laptop.
Configuring the identified port with the appropriate VLAN settings that match the network design of the PowerStore environment.
Ensuring that the port has the correct speed and duplex settings to communicate effectively with the discovery laptop.
Connecting the discovery laptop to the configured port to begin the discovery process of the PowerStore appliances.
This step is crucial as the discovery laptop is used to run the PowerStore Discovery Utility, which helps in identifying PowerStore appliances on the network and assists with the initial configuration1. For detailed instructions on configuring ToR switches and other networking components for PowerStore T, refer to the Dell PowerStore Networking Guide for PowerStore T Models2.
NEW QUESTION # 50
......
Pass rate is 98.45% for D-PST-MN-A-24 learning materials, which helps us gain plenty of customers. You can pass the exam and obtain the certification successfully if you choose us. D-PST-MN-A-24 exam braindumps contain both questions and answers, and it’s convenient for you to check the answers after practicing. You can try free demo before buying D-PST-MN-A-24 Exam Materials, so that you can know what the complete version is like. We provide you with free update for 365 days after purchasing, and the update version for D-PST-MN-A-24 exam dumps will be sent to you automatically. You just need to check your email and change your learning ways according to new changes.
Pdf D-PST-MN-A-24 Pass Leader: https://www.crampdf.com/D-PST-MN-A-24-exam-prep-dumps.html